MMM-System
+7-498-661-92-81
+7-498-661-61-35
Metal Magnetic Memory Method
MMM-System
Metal Magnetic Memory Method
New devices
TSC-7M-16
Tester of Stress Concentration TSC-7M-16
call
TSC-8M-4
Tester of Stress Concentration TSC-8M-4
call

Answers to frequently asked questions

Answers to frequently asked questions by specialists of Energodiagnostika Co. Ltd:

select
What are the delivery terms of instruments, scanning devices, sensors?
The delivery time of TSC type instruments is up to 30 calendar days.
Which set of equipment is recommended for non-contact magnetometric diagnostics (NCMD) of underground pipelines?
TSC-3M-12, TSC-5M-32 or TSC-7М-16 instrument as standard is recommended for NCMD of underground pipelines:
- with an additional Type 11-6W scanning device during the inspection of pipelines in urban conditions;
- with an additional Type 11-6WB scanning device during the inspection of pipelines in field conditions;
- with an additional Type 11-12W scanning device during the inspection of pipelines with the diameter of up to 500 m in urban conditions.
Which set of equipment is recommended for the inspection of pipelines, vessels and apparatuses?
In this case the TSC-3M-12, TSC-2M-8 or TSC-7М-16 instrument with a scanning g device Type 1-8M can be used to inspect welded joints as well as pipelines with small diameter from 40 to 108 mm, and it is recommended to purchase additionally:
- Type 2M scanning device for the inspection of pipes with the diameter of 20 to 40 mm, fillet welded joints and short welded joints;
- Type 6-12M scanning device for the inspection of pipeline and vessel surfaces with the coverage width up to 400 mm;
- eddy-current flaw detector EMIC-1M to detect cracks on the equipment surface in stress concentration zones without surface preparation directly on scale and paint coating.
Which set of equipment is recommended for the inspection of welded joints quality?
In this case the TSC instrument of any type as standard can be used, and it is recommended to purchase additionally:
- Type 2M scanning device for the inspection of fillet welded joints and short welded joints;
- Type 4M sensor for the inspection of local and remote/hard-to-reach areas;
- eddy-current flaw detector EMIC-1M to detect cracks on the equipment surface in stress concentration zones without surface preparation directly on scale and paint coating.
Which set of equipment is recommended for the inspection of automated well stock parts?
In this case it is recommended to use the TSC-3M-12, TSC-4M-16 or TSC-5M-32 in combination with the Type 6-8 scanning device with a set of arcs to diameters of 86, 92, 103 and 114 mm for the inspection of pump and fishneck housings, and it is recommended to purchase additionally:
- Type 2M scanning device for the inspection of grooves on fishnecks and base plates, gas separator components, as well as other irregular surfaces;
- Type 15-16 scanning device for the inspection of ESP shafts, EP and rods, supplied as a set with inserts to the shaft diameter (standard diameters are 17, 20, 22, 25 mm);
- eddy-current flaw detector EMIC-1M to detect cracks on the equipment surface in stress concentration zones without surface preparation directly on scale and paint coating.
Which scanning devices (SD) are recommended for the inspection of long surfaces?
The following devices are used for the inspection of long surfaces:
- Type 6-16M scanning device (a 16-channel SD with eight two-component sensors);
- Type 17-16M scanning device (a 16- channel SD with eight two-component sensors);
- Type 17-16 scanning device (a 16- channel SD with sixteen single-component sensors).
1
Page Size :
select
Items from 1 to 6 of 6
News
February 01, 2017
New TSC-9M-12
Fabrication of new device - Tester of Stress Concentration TSC-9M-12
December 01, 2013
New TSC-8M-4 device
Fabrication of new device - Tester of Stress Concentration TSC-8M-4
Price List
Energodiagnostika Co. Ltd is the main developer of a principally new non-destructive testing method and inspection instruments
based on application of the method of metal magnetic memory (MMM method).
1992-2017 © Energodiagnostika Co. Ltd. All Rights Reserved
Design by: Modern Media